A bridge has two parts that a scan cannot explain on its own. The connectors join the units, and the pontics replace the missing teeth. This post covers what each part controls, what 3Shape's own documents say about them in Dental System, and what to write on the work ticket when you outsource a bridge design.
It is written for lab owners and CAD/CAM technicians. It covers design settings, not clinical decisions. The 3Shape points come from a press release, a news article, a support page, release notes and a What's New document. Two of those sources date from 2015 and 2018, so menus in your version may look different. Implant bridges follow their own workflow in Dental System. For those, see 3Shape implant bridge design.
1. What connectors and pontics control
The definitions below are general lab terms, not 3Shape menu names.
A connector is the joint between two units of a bridge. Its height and width set how much material the joint has. Its position and shape set the open spaces between the units.
A pontic is the unit that replaces a missing tooth. Its outer shape has to sit in line with the teeth beside it. Its tissue side, where it meets the ridge, follows the form the dentist asks for.
2. Connectors in Dental System
3Shape's 2018 release of Dental System added "automatic creation and positioning of connectors" for bridge and bar design.
A bridge can also be split. A 2015 3Shape article says you "choose where to split the bridge using a male and female connector with two separate definable insertion directions."
Dental System also has a message for thin connectors. 3Shape's What's New document for Dental System 2025 (July 2025) lists a "Minimal connector thickness" notice for fixed restorations. It now shows as a non-blocking notification "to inform you about possible issues with manufacturing." Before that version, an error dialog paused the case until you clicked OK.
Recent release notes add three connector-related fixes. Dental System 24.1.0 (November 2024) resolved an issue with marking connectors during waxup bridge design, and fixed the distance map for frame bridge cases. Dental System 25.1.0 (September 2025) improved the connection of the bridge when connectors have self-intersections.
The 3Shape pages cited here do not say where the minimum connector value is set. For your version, check the current Dental System manual or ask your reseller.
3. Pontics in Dental System
Pontic shapes start from a library. A 3Shape support page from 2023 walks through it: open the Dental System Control Panel, select "Anatomy Elements", then "Anatomy and Pontic Libraries".
You can fill an empty library or change an existing one in two ways. Scan a model, or import a scanned model. When scanning, you can tick "Mirror Tooth" to save the mirrored tooth from the other side of the arch. The same page says that automatic crown design initialization needs a lower boundary and morph points on the scan: cusp, groove, occlusal contact point and vestibular zone.
The tissue side is a separate decision. The pontic form is the dentist's call, so it belongs on the work ticket.
4. What to tell a design partner about a bridge
A scan shows the preps, the gap and the bite. It does not show which pontic form the dentist wants, or the connector size your lab holds for a material. Write these on the work ticket: the tooth numbers with abutment teeth and pontic positions marked, the material and the mill or printer it goes to, the pontic form, any connector size you hold for that material, and your Dental System version.
SubDesignCenter designs single crowns, multi-unit bridges and full-contour restorations in 3Shape for dental labs and clinics worldwide. Send the prep, opposing and bite scans, plus a work ticket with the material and your design preferences. Designs are prepared for the material named on your work ticket. Each pontic is shaped to the form written on the ticket. If you give us a connector size for a material, we design to it and keep it on file for your lab, separately for each material.
SubDesignCenter also keeps each lab's contact strength, occlusal clearance, cement gap and minimum thickness on file and applies them to that lab's cases. For what those four values control, see 3Shape material settings and the cement gap. You can also send your 3Shape material settings file (.dme): we design with that material, and check whether the same material is already set up.
SubDesignCenter delivers the 3Shape design files in an editable form, along with production-ready files for your mill or printer. Whether you can open and edit them can depend on your Dental System version, so put your version on the work ticket. For everything else that goes with a case, see the case prep checklist. Need a ticket template? Our free dental lab Rx form runs in your browser and saves as a PDF.
Checklist
- Abutment teeth and pontic positions marked by tooth number
- Material and mill or printer named on the work ticket
- Pontic form written on the work ticket
- Connector size written down for each material you use
- Contact strength, occlusal clearance, cement gap and minimum thickness sent once
- Dental System version on the work ticket
Try it on three cases
New labs can send SubDesignCenter three free test cases: crowns, or bridges of up to 3 units, including implant bridges. For what to agree before the first case, see how to run three free test cases for 3Shape crown design outsourcing. To see prices, open the price list on our pricing page. Questions about your workflow? Reach us through the contact section on our site.